727 South Wolfe Street
Baltimore, MD 21231
Tel.: (410) 342-2626
Fax: (410) 342-7028 |
|
 |
|
|
DigiWx Tower System Specifications
Overall Height: 15 feet (fold-over scissor hinge at 7 feet) Tower height can be increased to 30 feet
- Construction: 3 x 3 treated aluminum painted white Counter-balanced tilt-over design
- Installation: Mounts on roof/deck/ground in 1/2 day. Allow 1 day for 30 ft tower installation
- Wind Speed: Machined metal construction 1 knot increments, 0-130 knots digital output
- Wind Direction: All-metal construction 3° increments, 1° to 360° digital outputs
- Temperature: Aspirated temperature, 1° increments, -40°C to +85°C digital output temperature compensated from 0°C to +55°C
- Humidity: 1% increments, 0 - 100% relative humidity
- Altimeter Setting: Accuracy (0.037 inches, 17.6 32.5 inches of Hg (must input field elevation via laptop);
- Power: 110/220-volts AC (50-60 hertz)
- Back-up Power: Optional 50W solar panel will keep 12-volt DC battery charged for year-round use
- Maintenance: 15 minute part replacement
- Upgradeable dual barometric pressure sensors with an accuracy +-0.01 RMSE and +-0.01 inches Hg, -40°C to +85°C temp range
|