AEPG 600/1000
Specifications
| Features | PDF
ALL ENVIRONMENTAL OPERATION:
- -65° to +135° F (-55° to +55° C) Operation Range
- Non-stick fluoropolymer collection orifice
- Optional event controlled low power heater
- Optional (Alter) wind shield...read more
HIGH RELIABILITY:
- 3 Independent transducers provide redundant measurement (auto compensates for trasducer failure)
- On-board processor compensates for temperature and environmental anomalies
- No moving parts
- No input restrictions
- Digital RS-232 output with Programmable format
MEETS TOUGH INTERNATIONAL GOV'T. REQUIREMENT:
- High Accuracy:+/- 0.01 inches (0.25mm) or 0.1% FS
- High Resolution: +/- 0.01 inches (0.25mm)
- 8" Diameter (50 in² Area ) or 16 cm Diameter (200 cm² Area) Collection Orifice
- Precipitation Rate: 0.01 in (0.25 mm)/hr. to 120 in. (304 cm)/hr.
- Capacity:24 inches (609 mm) or 40 inches (1016 mm)
EASY TO INSTALL AND MAINTAIN:
- 2 inch ID ANSI Schedule 40 Steel Pipe Mount with 3 screw level adjustment
- LED Fault isolation display
- Programmable Digital output to display and monitor performance variables
Belfort's years of experience in precipitation measurement is behind the development of this highly accurate state of the art all weather precipitation gauge. By combining proven mechanical design with no moving parts with the latest in electronic sensor technology, the AEPG series of sensors makes it possible to measure all types of precipitation in all weather conditions without human intervention and costly maintenance. By using the latest available technology and manufacturing techniques Belfort is able to offer this latest precipitation product at a fraction of the cost of older mechanical designs.
The All Environment Precipitation Gauge collects precipitation though a standard 8 inch (203.2mm) NWS orifice. Precipitation falls into a bucket which is supported by three precision sensors that weigh the precipitation amount independently and transmits the weight data to a central processing unit that compares each set of data and calculates the amount of precipitation. It converts this measurement into RS-232 format output for digital transmission to a recording device of customers selection. These pulses are transmitted as binary digital signals or as contact closures of a reed relay device.
Specifications
| Capacity: |
AEPG 600 24 inch (609mm)/
AEPG 1000 40 inch (1016mm) |
| Collection Area: |
200 cm² (16 cm diam.) or
50.26 in² (8 inch diam., AEPG600 only) |
| Precipitation Rate: |
Range 0.01 in (0.25 mm)/hour
to 120 in. (304 cm)/hour |
| Resolution: |
0.01 in. (0.25mm) |
| Repeatability: |
+/- 0.01 in.(0.25) |
| Accuracy: |
+/- 0.01 inch (0.25mm)
or 0.1% FS |
| Output: |
RS232 configurable to provide inch or metric weight equivalent amount of precipitation (optional trasducer frequency output) |
| Power Requirements: |
8-18 volts DC, (3 watts nominal) Optional heaters: 115 vac,
60 cycle, 2 amps (activated by precipitation event) |
| Operating Tempurature: |
-65° to +135° F (-55° to +55°C) |
| Storage Tempurature: |
-85° to +300° F (-65° to +150°C) |
| Construction: |
Aluminum with High Impact UV resistant thermal plastic insulating cover |
| Weight: |
28.5 lbs (13 kg) |
Standard Features
- Non-Stick fluoropolymer coated collection orifice
- 24 inch (609mm) capacity, 50.26 in²/8 inch diam, collection orifice
- 0.001 inch resolution RS232 output
- Standard 2 inch ID ANSI Schedule 40 pipe mount
Options
- Heated Collection orifice (P/N 36002)
- 4 ft Diameter Alter (wind) Shield (P/N 36001-1) or 8 ft Diameter Alter (wind) Shield (P/N 36001-2)
- Data Output Options:
- In/mm
- Total weight
- Transducer Frequency/weight
Ordering Information
| Model |
Description |
Part No. |
AEPG 600 |
24 inch (609mm)capacity
50.26 in² collection area/8 inch diameter |
36000-6 |
| AEPG 600M |
24 inch (609mm)capacity
200 cm² collection area/16 cm. diameter |
36000-6M |
AEPG 1000M |
40 inch (1000mm)capacity
200 cm² collection area/16 cm. (6.3 in) diameter |
36000-1M |
|