R3-50Gill Instruments: HS-50

Key Features:

  • Maintenance Free
  • Robust Construction
  • 50Hz Data Rate
  • Speed of Sound and Sonic Temp Outputs
  • Custom Calibrated
  • Analogue Outputs

The Solent Research R3-50 is a cost effective solution for projects requiring the benefit of Gill's proven experience in the production of ultrasonic anemometers for all weather applications. Robust and easy to use, the R3-50 employs the same software as the popular R3 range of sensors but with a data rate of 50 Hz.

If required the unit can be supplied with the optional Sensor Input Unit (for analogue inputs) and Power Supply (including analogue outputs).

Based on the highly successful range of Solent Research Anemometers, the R3-50 is ideal for users undertaking research with eddies at high mast levels.

Having identical output formats to the R3, the R3-50 is particularly suited to applications where a complete wind profile is required, with an R3 or HS positioned near the ground and the R3-50 positioned at a higher level.

Gill research grade units are individually custom calibrated and supplied with a certificate of calibration. All of our test equipment has been designed specifically to test and calibrate our range or ultrasonic sensors and is traceable to national standards. A number of orderable options are available including:

  • Power supply (PCIA)
  • Travelling case
  • Analogue and PRT inputs via Signal Interface Unit (SIU)

PDF File R3-50 (PDF file)

Specifications

Wind Speed
Range 0-45 m/s
Accuracy <1% RMS
Resolution 0.01 m/s
   
Direction
Range 0-359°
Accuracy* <±1° RMS
Resolution
   
Speed of Sound
Range 300-370 m/s
Resolution 0.01/s
Accuracy <±0.5%@20°C
   
Measurement
Ultrasonic output rate 50Hz
Parameters UVW, Speed of Sound
   
Digital Output
Communication RS422 full duplex, 8 data bits, 1 stop bit, no parity
Baud rates 2400-115200
Output rate Selectable 0.4-50s-1
   
PRT Input
Input Resolution 0.01°C
Input Accuracy <0.01°C (from 0° to 50°C)
<0.15°C (from -40° to +60°C)
Analogue Outputs (Via supplied PCIA)
Quantity 7(U, V, W, SoS, PRT+2 analogue inputs
Scale ±10, ±20, ±30, ±60 m/s
Update rate 0.4 to 50s-1
Range/resolution ±2.5V, 14 bits
Accuracy <0.25% of FSR
   
Analogue Inputs (requires SIU)
Quantity 6 differential inputs
Sampling Rate 50s-1
Range/Resolution ±5V, 14 bits
Accuracy <0.1% of FSR
   
Power Requirement
Anemometer 9-30VDC <4w (eg. <150mA % 24VDC or 300mA @12VDC
   
Mechanical
Material Aluminum/Carbon Fibre
Size 750mm x 240mm
Weight 1.0kg
   
Environmental
Protection Class IP65
Operating temperature -40°C to +60°C
Precipitation Operate to 300mm/hr
EMC BS EN 50081-1:1992 Emmissions
BS EN 50082-1: 1992 Immunity
Suitable for exposure to a marine environment
*Accuracy spec applies for wind speed <32 m/s and for wind incidence up to ±20º from the horizontal

 

Typical Applications

  • Wind Turbulence Measurement
  • Component Wind Velocity UVW
  • Wind Profiling

 

Dimensions

R3-50 Dimensions

The R3-50 is part of the Solent range of ultrasonic anemometers. The range is in continuous development and therefore specifications may be subject to change without prior notice.