Belfort Instrument logo The Standard of Measurement
Homepage
About Belfort
News
Belfort Blog
Meteorological Sensors
Store
Aviation Systems
Kelly Cole, Ralph Petragnani, Bruce R. Robinson, Nicholas C. Kaufman, Debra S. Alascio, Belfort Instrument, Weather, ASOS, AWOS, Digiwx
Installations
Military and Industrial
Customer Services
Reference Library
727 South Wolfe Street
Baltimore, MD 21231
Tel.: (410) 342-2626
Fax: (410) 342-7028
Wind < Back to Wind page

R3-50Gill Instruments: WindMaster

Key Features:

  • Maintenance Free
  • Lightweight Construction
  • U, V, W, SOS & Sonic Temp Output
  • 20Hz or Optional 32Hz Data Rate
  • Optional Analogue Inputs and Outputs

The new WindMaster three axis anemometer is a robust instrument based on time of flight measurements and is essential in the understanding of turbulent flows, surface energy balance and scalar fluxes.

All these areas of research rely on accurate and precise measurements of mean and variance of (time averaged) wind velocities and Speed of Sound (SOS) derived temperature.

This is particularly true in determining scalar fluxes using the eddy covariance technique. Gill employs the optimum mechanical configuration and electronic processing to minimise flow distortion and transducer shadow effects. Gill undertakes an individual calibration with a Gill wind tunnel test on each unit to provide the optimum performance. The WindMaster is available with a 20Hz data output rate with an option to increase this to 32Hz. The instrument is constructed in the familiar Aluminium/carbon fibre construction. The WindMaster is fitted with field proven standard Gill transducers with the ability to measure a top wind speed of 45 m/s.

Both software and electronics have been enhanced to provide improved vertical (W) resolution and SOS accuracy. New design electronics has facilitated a reduction in power consumption to 55 mA at 12 V dc, a significant advantage when used on power sensitive sites.

A number of orderable options are available including:

  • Increase in data output rate to 32 Hz
  • 4 analogue output channels with options for 12 or 14 bit resolution.
  • 4 analogue input channels, with options for 12 or 14 bit resolution.
  • A flange mounting arrangement is provided as standard, with option to order a different mounting.
  • Wind tunnel calibration in accordance with ISO 16622 and traceable to national standards.
  • Travelling case

PDF File WindMaster (PDF file)
PDF File WindMaster Pro (PDF file)

Specifications

Wind Speed
Range 0-45 m/s
Resolution 0.01 m/s
Accuracy* <1.5% RMS @ 12 m/s
Accuracy* <1% RMS @ 12 m/s (Custom)
   
Direction
Range 0-359°
Resolution 0.1°
Accuracy 2° @ 12 m/s
Accuracy 0.5° @ 12 m/s (Custom)
   
Sonic Temperature
Range -40°C to +70°C
Resolution 0.01°C
   
Speed of Sound
Range 300-370 m/s
Resolution 0.01 m/s
Accuracy <±0.5%@20°C
   
Measurement
Internal sample rate 20Hz or 32Hz
Output Parameters 1, 2, 4, 8, 10, 16, 20 & 32 (Option) Hz
Units of Measure m/s, mph, kph, knots, ft/min
Formats UVW, POlar or NMEA
Averaging Flexible 0-3600 s
Digital Output
Communication RS232, 422, 485
Baud rates 2400-115200
Format ASCII
 
Analogue Outputs - Optional
Resolution 12 or 14 bits 4 channels available
Selectable Range User selectable full scale wind speed
Output Type 0-20mA, 4-20mA, 0-5V, ±2.5V, ±5V
   
Analogue Inputs - Optional
Resolution 12 or 14 bits Up to 4 single ended or 2 differential
Input Type ±5V
   
Power Requirement
Anemometer 9-30V DC (25mA @12V DC)
   
Mechanical
Size 750mm x 240mm
Weight 1.0kg
   
Environmental
Protection Class IP65
Operating temperature -40°C to +70°C
Humidity < 5% to 100% RH
Precipitation Operate to 300mm/hr
EMC Emissions BS EN 61000 - 6 - 3
Immunity BS EN 61000 - 6 - 2
*Accuracy spec applies for wind speed, and for wind incidence up to ±30º from the horizontal

 

Typical Applications

  • Meteorological Systems
  • Transport Safety
  • Structural Safety
  • Wind Profiling
  • Marine Research
  • Wind Turbine Site Survey

 

Dimensions

R3-50 Dimensions

The WindMaster is part of the Solent range of ultrasonic anemometers. The range is in continuous development and therefore specifications may be subject to change without prior notice.

©2012, Belfort Instruments, All rights reserved | Site designed by: The Canton Group